<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-19 19-51-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 50 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 71 kHz 14581 10,1708
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 5,30 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 71 kHz MIN: 12 kHz % above 76 kHz: 10,1708 Acquired: 2026.08.19 19.50.48 Total samples: 14581 Equivalent time: 0:12:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,1 dBr MIN: 4,3 dBr AVE: 5,30 dBr % above 12,2 dBr: 0,0 Last value: 5,9 dBr (2026.08.19 19.50.48) 19.36 19.38 19.40 19.42 19.44 19.46 19.48 19.50 0 2 4 6 Pm [dBr]